Misuse Of Sockets
Leave a message
With the popularization of household appliances, the number of power sockets at home is also increasing. However, if it is not properly installed, it will become a "hidden bomb" buried in the wall. According to the relevant survey data of the Ministry of Public Security, among the accumulated fire accidents in China in the past 10 years, the fire caused by short circuit of power sockets, switches, circuit breakers and other reasons accounted for nearly 30% of the total, ranking first among all kinds of fires.
Position too low
When installing sockets in many families, they feel that too high is not beautiful, and they will be installed in a lower concealed position. However, Dr. Xia Dong, from the Institute of Electrical Engineering of the Chinese Academy of Sciences, said that it was easy to splash water into the socket when mopping the floor, which would lead to an electric leakage accident. According to the industry regulations, the distance between the exposed socket and the ground should not be less than 1.8 meters; The concealed socket shall not be less than 0.3m from the ground. The socket of kitchen and toilet shall be more than 1.5m above the ground, and the socket of air conditioner shall be more than 2m at least.
Random installation
The power conductor must use a copper wire cross-section. If you live in an old house, you must replace the original aluminum wire with copper wire. Because the aluminum wire is very easy to oxidize, the joint is easy to ignite. An investigation has shown that the incidence of electrical fire in residential buildings using aluminum wire is dozens of times higher than that of copper wire. In addition, in order to look beautiful, many families will adopt the method of grooving and laying buried lines and concealed pipes. Xia Dong reminds that when wiring, the principle of "live wire into the switch, zero wire into the lamp head" must be followed, and leakage protection devices must be set on the sockets.
Lack of protection
There is often water and lampblack in the kitchen and bathroom, so it is better to install a splash box or plastic baffle on the socket panel.
In addition, some decoration companies often make the ground wire useless when installing the three hole socket, or even directly connect the ground wire to the gas pipeline. Professionals point out that these practices are very dangerous. The ground wire is connected to the electrical enclosure, and once the electrical leakage occurs, it will cause electric shock.
Share
This practice will overload the electrical appliances and cause fire. It is better to use independent sockets for high-power appliances such as air conditioners, washing machines and range hoods. Generally speaking, it is better to install 4 sets of sockets in the bedroom, one set per 2.5 square meters in the living room and one set per 1.2 square meters in the kitchen.
Few loops
The old house has only one circuit. Once any circuit is short circuited, the whole room will be paralyzed. Generally speaking, two or three circuits can be selected for the socket, one for the kitchen and one for the bathroom, and one for the air conditioner.
Use the old national standard
Universal socket, that is, the jack can be compatible with two or three poles at the same time, or even non daily plugs such as British, American and European standards. However, due to the large jack of this type of socket, the contact area between the socket connector and the electrical plug is too small, which is easy to overheat the contact plate and cause fire accidents.
Two core sockets are easy to distinguish from each other in terms of appearance. All plug boards have three pole jacks, but the plug of the socket itself has only two pins. They are two core problem sockets. This type of socket lacks a ground wire. In the process of use, once an insulating part inside the appliance is damaged, the current will spread all over the surface of the appliance. Since the current cannot be introduced into the ground through the two core socket, it is very easy to cause an electric shock accident.